JA Delmas

LEGAL NOTICE & CREDITS © 2024 Burkina Equipements

JA Delmas

HOME BRANDS & PRODUCTS CAT PRODUCT LINE POWER SYSTEMS ELECTRIC POWER GENERATION ATS MX CONTACTOR CTG SERIES AUTOMATIC TRANSFER SWITCH

CTG SERIES AUTOMATIC TRANSFER SWITCH

Back to the list

<br>The Cat® CTG Series Automatic Transfer Switches (ATS) are pre-configured for applications requiring the dependability and ease of operation found in a full feature power contactor type transfer switch.</br> <br>CTG switches are equipped with the next generation MX150 microprocessor panel, which controls the operation and displays the status of the transfer switch’s position, timers and available sources. As an embedded digital controller, the MX150 offers high reliability and ease of unattended operation across a range of applications.</br>

SPECIFICATIONS

Rating Range40-3000A

Transfer TypeOpen transition

Switch TypeContactor based

technical summary

Rating Range40-3000A

Transfer TypeOpen transition

Switch TypeContactor based

CTG Series Automatic Transfer Switch STANDARD EQUIPMENT

  • standard features
    Auxiliary Contact:
    Closed when the switch is in the emergency position
    (Additional contacts optional)
    Auxiliary Contact:
    Closed when the switch is in the normal position
    (Additional contacts optional)
    7, 14, 28 day interval timed exerciser, pushbutton/timer operation
    Engine Start Contact
    Indicating LED Pilot Lights:
    -Switch in emergency position
    -Switch in normal position
    - Normal source available
    -Emergency source available
    Time Delay to Engine Start: Standard setting 3 seconds, adjustable 0-10 seconds
    In-Phase Monitor, self-adjusting (Not available on CTGD models)
    Time Delay on Retransfer to Normal: To delay retransfer to normal source (immediate retransfer on generator set failure); standard setting 30 minutes, adjustable 0-60 minutes
    Push button Bypass of time delay and normal emergency
    Test Switch – Momentary
    Event Log OD 16 Event that track date, time, reason and action taken
    Voltage and Frequency Indication for S1 and S2
    Peak Shave/Remote Load Test: Input for peak shave or remote load test; includes automatic return to normal if emergency source fails and normal is present; 120 VAC
    When specified for use with a CTGD Series delayed transition switch, the control panel also includes the following:
  • mx150 control panel
    Time Delay for Engine Cool Down: Allows engine to run unloaded after switch retransfer to normal; standard setting 5 minutes, adjustable 0-60 minutes
    Time Delay on Transfer to Emergency: To delay transfer to emergency after verifying emergency source available; standard setting 1 second, adjustable 0-5 minutes
    Timer and voltage/frequency settings adjustable without disconnection from power sources
    Built-in diagnostics with LCD display for immediate troubleshooting
    LED/LCD indicators for ease of viewing and long life
    Nonvolatile memory (exerciser battery backup not required for standard operation)
    Processor and digital circuitry isolated from line voltage
    Inputs opto-isolated for high electrical immunity to transients and noise
    Communications header for network interface

CTG Series Automatic Transfer Switch OPTIONS

    • options
      Plant Exerciser, clock type (load/no load): Allows the generator to start and run unloaded or to simulate a power failure, start generator and run under load (7-14-28-365 days, user selectable)
      Space heater and thermostat
      Network communications interface card (LonWorks / ModBus)
      Maintained Test Switch
      Maintained Test Switch w/Keypad
      Service entrance configuration
      Auxiliary Contact, operates on Source 1 line failure
      Auxiliary Contact, operates on Source 2 availability
      Auxiliary Contacts: Closed when the transfer switch is in Source 2 position
      Auxiliary Contacts: Closed when the transfer switch is in Source 1 position
      Disconnect Switch: Permits transfer in “AUTO” position and inhibits transfer in “INHIBIT” position. (Standard 800A and above)
      Elevator Pre-Signal Auxiliary Contacts: Open 0-60 seconds prior to transfer to either direction, re-closes after transfer
      Universal Motor Load Disconnect Circuit: Auxiliary Contact opens 0-60 seconds prior to transfer in either direction, re-closes after transfer. Can be configured by end user for Pre-transfer, Post-transfer, or both.
      Voltage Imbalance Monitor (Three Phase)
      Lockable, see-through cover for ATS controller
      Power Measurement Meters
      Note:For applications requiring additional options or other configurations, see the CTS Series fully configurable transfer switch.
Back

MOTEUR