Back to the list

Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Contactor -based Bypass Isolation ATS are available from 100A to 1200A.

SPECIFICATIONS

Rating Range100 to 1200A

Transfer TypeBypass Isolation

Switch TypeContactor Based

technical summary

Rating Range100 to 1200A

Transfer TypeBypass Isolation

Switch TypeContactor Based

ratings

Control Power100-1200A 2-, 3-, 4-pole

System Voltage Application120 - 600 Vac, 50/60 Hz

WithstandUp to 65 kAIC withstand

Applicable TestingCSA C22.2 No. 178 certified
IBC 2006, CBC 2007 and OSHPD

ATC Contactor Based Bypass Isolation Automatic Transfer Switch STANDARD EQUIPMENT

  • controls and wiring
    All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
  • enclosure
    Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

ATC Contactor Based Bypass Isolation Automatic Transfer Switch OPTIONS

    • available options
      Drawout capabilities on both ATS bypass portions and power switching devices completely interchangeable between ATS and bypass units
      Open, closed or delayed transition
      2- or 4-position test switch
      Multi-meter options available
      Selectable automatic or non-automatic operation
      Space heaters
      Load sequencing contacts
      Surge suppression
      Remote communications
      Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
      Field selectable, multi ratio, control voltage transformer 50/60 Hz
      Dual drawout type is field configurable for top or bottom conduit entry
    • optional delayed transition includes
      Time delay neutral
      Pre-transfer signal with 1 N.O. and 1 N.C. contacts